We differ between zone/user scenes (0..63) and apartment scenes (64..127). The zone/user scenes are usually called with a group > 0, apartment scenes are usually called in a whole zone or apartment using the broadcast group (=0).

The following list uses the term "zone pushbutton" which means a normal digitalSTROM pushbutton. An "area pushbutton" is a button which controls a subset out of all devices of the same color. With an area pushbutton it is possible to control e.g. a single lamp while the zone pushbutton controls all lamps in a room.
digitalSTROM supports one zone pushbutton and up to four area pushbuttons per color per room.

zone/user scenes

0 - off scene called from zone pushbutton (Aus)
1 - off scene called from area pushbutton 1 (Bereich 1 Aus)
2 - off scene called from area pushbutton 2 (Bereich 2 Aus)
3 - off scene called from area pushbutton 3 (Bereich 3 Aus)
4 - off scene called from area pushbutton 4 (Bereich 4 Aus)
5 - scene 1 called from zone pushbutton (Stimmung 1)
6 - scene 1 called from area pushbutton 1 (Bereich 1 Ein)
7 - scene 1 called from area pushbutton 2 (Bereich 2 Ein)
8 - scene 1 called from area pushbutton 3 (Bereich 3 Ein)
9 - scene 1 called from area pushbutton 4 (Bereich 4 Ein)
10 - dim continue (area pushbutton 1..4)
11 - dim down one step (zone pushbutton)
12 - dim up one step (zone pushbutton)
13 - minimal value of a device (light off, blinds down, marquee in, ...)
14 - maximal value of a device (light max. on, blinds up, marquee out, ...)
15 - stop (zone pushbutton)
16 - <reserved>
17 - scene 2 called from zone pushbutton (Stimmung 2)
18 - scene 3 called from zone pushbutton (Stimmung 3)
19 - scene 4 called from zone pushbutton (Stimmung 4)
20 - scene 2 called from area pushbutton 1 (Stimmung 12)
21 - scene 3 called from area pushbutton 1 (Stimmung 13)
22 - scene 4 called from area pushbutton 1 (Stimmung 14)
23 - scene 2 called from area pushbutton 2 (Stimmung 22)
24 - scene 3 called from area pushbutton 2 (Stimmung 23)
25 - scene 4 called from area pushbutton 2 (Stimmung 24)
26 - scene 2 called from area pushbutton 3 (Stimmung 32)
27 - scene 3 called from area pushbutton 3 (Stimmung 33)
28 - scene 4 called from area pushbutton 3 (Stimmung 34)
29 - scene 2 called from area pushbutton 4 (Stimmung 42)
30 - scene 3 called from area pushbutton 4 (Stimmung 43)
31 - scene 4 called from area pushbutton 4 (Stimmung 44)
32 - off scene called from scene extender pushbutton 1 (Stimmung 10)
33 - on scene called from scene extender pushbutton 1 (Stimmung 11)
34 - off scene called from scene extender pushbutton 2 (Stimmung 20)
35 - on scene called from scene extender pushbutton 2 (Stimmung 21)
36 - off scene called from scene extender pushbutton 3 (Stimmung 30)
37 - on scene called from scene extender pushbutton 3 (Stimmung 31)
38 - off scene called from scene extender pushbutton 4 (Stimmung 40)
39 - on scene called from scene extender pushbutton 4 (Stimmung 41)
40 - <reserved>
41 - <reserved>
42 - dim down one step (area pushbutton 1), use scene 10 to continue
43 - dim up one step (area pushbutton 1), use scene 10 to continue
44 - dim down one step (area pushbutton 2), use scene 10 to continue
45 - dim up one step (area pushbutton 2), use scene 10 to continue
46 - dim down one step (area pushbutton 3), use scene 10 to continue
47 - dim up one step (area pushbutton 3), use scene 10 to continue
48 - dim down one step (area pushbutton 4), use scene 10 to continue
49 - dim up one step (area pushbutton 4), use scene 10 to continue
50 - local off scene (called internally from local pushbutton)
51 - local on scene (called internally from local pushbutton)
52 - stop (area pushbutton 1)
53 - stop (area pushbutton 2)
54 - stop (area pushbutton 3)
55 - stop (area pushbutton 4)
56..63 - <reserved>

apartment scenes

64 - auto standby
65 - panic
66 - energy overload
67 - standby
68 - deep off
69 - sleeping
70 - wake up
71 - present
72 - absent
73 - bell signal
74 - alarm signal
75 - room wakeup
76..111 - <reserved>
112..127 - free for individual usage